This is a second edition of a comprehensive Specification providing minimum requirements for the post-tensioning system component testing and acceptance, design, and installation of multistrand and grouted post-tensioning systems. Based on proven knowledge and developed with the ANSI consensus process, it addresses the selection of tendon protection levels, system components, materials, installation, and stressing of post-tensioning tendons. It provides requirements and guidance for furnishing complete post-tensioning systems and all required accessories, including but not limited to anchorages, local zone reinforcement, ducts, pipes, strands, and bars from a single supplier, as required. Provisions further address submittal samples, drawings, calculations, procedures, reports, manuals, and certifica¬tions. Both temporary and permanent post-tensioning is covered in this Specification.

This Specification should be used in its entirety to avoid unnecessary differences in requirements and provisions out of context. It is primarily intended for use in bridges but is also applicable to a wide variety of structure types, including buildings. The companion document PTI M55.1, Specification for Grouting of Post-Tensioned Structures, should be used in conjunction with this document.

One of the major features of this edition is the addition of a Commentary that provides guidance for most mandatory provisions of the Specification. Grouting related items that are installed with the ducts are now included. The PT duct provisions are expanded to allow for use of either fib Bulletin 7 or 75, depending on project needs. Pourback details are provided in the Appendix. Many other provisions received smaller revisions.

64 pages; 8.5 x 11 in. (soft cover)

Published August 2019

 

Table of Contents

1.0 — INTRODUCTION

1.1 — General description

1.2 — Alternative post-tensioning scheme

1.3 — Referenced standards and specifications

2.0 — DEFINITIONS AND ABBREVIATIONS

2.1 — Definitions

2.2 – Abbreviations

3.0 — POST-TENSIONING SYSTEM (PTS) TENDON PROTECTION LEVELS (PL)

3.1 — Protection Level 1A (PL-1A)

3.2 — Protection Level 1B (PL-1B)

3.3 — Protection Level 2 (PL-2)

3.4 — Protection Level 3 (PL-3)

4.0 — MATERIAL AND PERFORMANCE REQUIREMENTS

4.1 — General

4.2 — Material standards

4.2.1 — Strand

4.2.2 — Bar

4.2.3 – Special prestressing materials

4.3 — Component standards

4.3.1 — General

4.3.2 — Post-tensioning anchorages

4.3.3 — Permanent grout caps

4.3.4 — Bar couplers

4.3.5 — Duct

4.3.5.1 — Corrugated metal duct

4.3.5.2 — Corrugated plastic duct

4.3.5.3 — Smooth HDPE duct

4.3.6 — Duct connections and fittings

4.3.7 — Heat-shrink sleeves

4.3.8 — Precast segmental duct couplers

4.3.9 — External smooth HDPE duct connections

4.3.10 — Rigid ducts and steel pipes

4.3.11 — Connection tolerance between pipe and duct

4.3.12 — Inlets, outlets, valves, and plugs

4.4 — System approval testing

4.4.1 — Post-tensioning anchorages

4.4.2 — Grouting component assembly pressure test (PL-1B, PL-2, and PL-3 only) and system safety proof test (PL-1A only)

4.4.3 — Duct testing

4.4.4 — Corrugated plastic duct

4.4.5 — System pressure tests

4.4.5.1 — Corrugated plastic duct connections

4.4.5.2 — Precast segmental duct couplers

4.4.5.3 — Internal duct systems

4.4.5.4 — External duct systems

5.0 — INSTALLATION DRAWINGS AND STRESSING CALCULATIONS

5.1 — General

5.2 — System drawings

5.3 — Tendon drawings

5.3.1 — Plans and elevations

5.3.2 — Sections

5.3.3 —Measurements

5.3.4 — Tolerances

5.3.5 — Stressing data

5.3.6 — Material take-off

5.3.7 — Temporary openings for PT work

5.3.8 — Installation requirements

5.4 — Stressing calculations

6.0 — QUALITY ASSURANCE AND QUALITY CONTROL (QA/QC)

6.1 — QA program

6.2 — Procurement

6.3 — Project quality plan

6.4 — Receiving

6.4.1 — Wedges

6.4.2 — Prestressing steel

6.4.3 — Anchorages

6.5 — Identification and traceability of materials

6.6 — Sampling of prestressing material

6.7 — Defects during installation

7.0 — PERSONNEL QUALIFICATIONS

7.1 — Supervision

8.0 — SHIPPING AND STORAGE OF MATERIALS

8.1 — General

8.2 — Anchorages

8.3 — Wedges

8.4 — Metal duct

8.5 — Plastic duct

8.6 — Strand

8.7 — Bars

8.8 — Cement and grout

8.9 — Accessories

9.0 — BEARING PLATE AND DUCT INSTALLATION

9.1 — General

9.2 — Measurements

9.3 — Tolerances

9.4 — Anchorage components

9.5 — Deviation pipes

9.6 — Ducts

9.7 — Accessories

9.8 — Splices and joints

9.9 — Location of grout inlets and outlets

10.0 — PLACING CONCRETE

10.1 — Precautions

10.2 — Proving of post-tensioning ducts

10.3 — Problems and remedies

11.0 — PRESTRESSING STEEL INSTALLATION

11.1 — General

11.2 — Strand

11.3 — Bar

11.4 — Corrosion protection

11.5 — Acceptance criteria

12.0 — STRESSING OPERATIONS

12.1 — General

12.2 — Maximum stress at jacking

12.3 — Stressing sequence

12.4 — Stressing jacks and gauges

12.5 — Calibration of jacks and gauges

12.6 — Elongations and agreement with forces

12.7 — Friction testing

12.8 — Wire failures in strand tendons

12.9 — Cutting of post-tensioning steel

12.10 — Capping of tendons

12.11 — Record of stressing operations

13.0 — GROUTING OPERATIONS

13.1 — Duct air test

14.0 — PROTECTION OF POST-TENSIONING ANCHORAGES

14.1 — General

14.2 — Pourbacks

14.3 — Anchorage coating system

15.0 — REPAIRS OF HOLES AND ACCESS OPENINGS

15.1 — Openings

16.0 — REFERENCES

APPENDIX A – TYPICAL POURBACK DETAILS AND INLET AND OUTLET DETAILS

APPENDIX B – TYPICAL REPAIR DETAILS FOR ACCESS OPENINGS, BLOCKOUTS, AND HOLES

ADDENDA AND ERRATA INFO

Any applicable addenda or errata are included with individual documents at the time of purchase. For a listing of and access to all product addenda and errata, visit the Addenda and Errata page. Errata page.

Return/Exchange Policy

Printed / Hard Copy Products: If your order is damaged, defective, or incorrect, we acccept its return without question within 30 days of purchase. Returns shipped COD are not accepted. University bookstores and other resellers must receive authorization from PTI to return books in resaleable condition. Authorized returns in resaleable condition are subject to 15% restocking fee.

Electronic /Downloaded Products & Online Learning Courses: These items are not eligible for return.